Units for Solvent Recycling
LÖMI Vacuum Distillation Units
Our units with fully automatic operation are capable of reprocessing all organic
solvents in outstanding quality. The throughput capacity depends on the solvent, as well as the kind and degree
of its pollution.
Integration into existing purification processes is possible in a fast
and economical way. By employing a specific vacuum technology, our systems are capable of
reprocessing organic solvents with a boiling point of up to 285 °C.
Technical Specifications
Valid from 30 March 2004.
With the publication of this list, all other lists become void.
The technical specifications stated below are to be considered as an orientation, since each
unit is developed and manufactured specifically according to your needs.
Prices on application!
In the Download Section, you will find our
Brochure Vacuum Distillation Units as a PDF document.
| Model |
LRA-50 |
LRA-150 |
LRA-250 |
LRA-400 |
LRA-600 |
LRA-1200 |
LRA-1600 |
LRA-2000 |
LRA-3000 |
| |
 |
 |
 |
 |
 |
 |
| |
| Overall capacity |
50 l |
150 l |
250 l |
400 l |
600 l |
1200 l |
1600 l |
2000 l |
3000 l |
Operating capacity
min. – max. |
25 – 30 l |
75 – 100 l |
140 – 170 l |
250 – 300 l |
350 – 450 l |
700 – 900 l |
1000 – 1200 l |
1200 – 1500 l |
1800 – 2200 l |
| Nominal distillation rate, depending on solvent and degree of pollution |
8 – 20 l/h |
25 – 60 l/h |
30 – 80 l/h |
60 – 140 l/h |
80 – 180 l/h |
120 – 280 l/h |
150 – 350 l/h |
200 – 500 l/h |
300 – 800 l/h |
| |
| Operating temperature |
max. 200 °C |
| Operating pressure |
-1,0 to +0,5 bar |
| Thermo-oil heating |
integrated |
external |
| |
| Protection class |
ATEX 94/9/EC (ATEX 95) –
II 2 G c T3 |
Voltage, frequency
(others upon request) |
400 V, 3 Ph, 50 Hz |
| Operating power input of heating |
5,0 kW |
13,0 kW |
20,0 kW |
30,0 kW |
40,0 kW |
60,0 kW |
70,0 kW |
80,0 kW |
100,0 kW |
| Overall power input, average |
2,9 kW |
6,0 kW |
11,0 kW |
16,0 kW |
21,0 kW |
31,0 kW |
41,0 kW |
43,0 kW |
55,0 kW |
| |
| Overall width |
600 mm |
750 mm |
850 mm |
2400 mm |
2800 mm |
2800 mm |
2800 mm |
2800 mm |
3200 mm |
| Overall height |
1800 mm |
1800 mm |
1800 mm |
2800 mm |
3200 mm |
3900 mm |
4100 mm |
4300 mm |
4600 mm |
| Overall depth |
1420 mm |
2000 mm |
2000 mm |
1600 mm |
1700 mm |
1700 mm |
1700 mm |
1700 mm |
2000 mm |
| Net weight approx. |
250 kg |
400 kg |
500 kg |
800 kg |
900 kg |
1400 kg |
1500 kg |
1600 kg |
2000 kg |
Corresponding Vacuum Units |
| Model |
LÖ/V 6 |
LÖ/V 30 |
LÖ/V 30 |
LÖ/V 30 |
LÖ/V 30 |
LÖ/V 55 |
LÖ/V 55 |
LÖ/V 95 |
LÖ/V 125 |
| |
| Vacuum pressure max. |
80 mbar |
50 mbar |
50 mbar |
50 mbar |
50 mbar |
50 mbar |
50 mbar |
50 mbar |
50 mbar |
| Max. suction capacity at 15 °C |
10 m³/h |
30 m³/h |
30 m³/h |
30 m³/h |
30 m³/h |
55 m³/h |
55 m³/h |
95 m³/h |
130 m³/h |
| Weight approx. |
50 kg |
65 kg |
65 kg |
80 kg |
80 kg |
95 kg |
100 kg |
115 kg |
140 kg |
Specifications are subject to alteration.
|